Benchtop Conductivity Meter : Benchtop Conductivity Meter LBCM-A14


Share :



Benchtop Conductivity Meter LBCM-A14 with 1 to 3 points push button conductivity calibration, automatically recognizes calibration standards. With setup menu, it does setting of 6 parameters calibration points, temperature units and others. Large LCD display shows settings and measurement values. Temperature calibration by manual method improves the accuracy of conductivity meter.



Available Range :

Conductivity measurement range : 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cm Conductivity measurement range : 0.000 μS/cm to 3000mS/cm Conductivity Mode : Conductivity measurement range : 0.01-20.0, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm TDS Mode : TDS measurement Range : 0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt) Temperature Mode : Temperature range : 0 to 105°C, 32 to 221°F Cell constant : K=0.1, 1, 10
Conductivity Mode
Conductivity measurement range0.01-20.0, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
Conductivity accuracy±1% F.S.
Conductivity resolution0.001, 0.01, 0.1, 1
Conductivity calibration points1 to 3 points
Conductivity calibration solutions10 µS/cm , 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm
TDS Mode
TDS measurement Range0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)
TDS Accuracy± 1 % F.S.
TDS Factor0.01 to 1.00 (default 0.5)
TDS Calibration points3 points
Temperature Mode
Temperature range0 to 105°C, 32 to 221°F
Temperature accuracy±1°C
Temperature resolution0.1°C, 0.1°F
Temperature calibration points1 point
Temperature Compensation Range and ModeManual or Automatic, 0 to 100°C , 32 to 212°F
Temperature coefficient0.0 to 10.0 % per °C
Cell constantK=0.1, 1, 10
Power requirementsDC 9 V, using AC adapter, AC 220 V, 50 Hz
Dimension (L×W×H)210 × 205 × 75 mm
Weight1.5 kg
  • Measures conductivity, TDS, Temperature of the liquids
  • Automatic temperature compensation for accurate values over the entire range
  • Selectable temperature units (°C or °F) for different application requirements
  • Reset function automatically resumes all the setting back to factory default options
  • Manual and automatic mode of temperature calibration
  • Auto hold feature to lock, record and read stable measurement endpoint
  • Stability indicator displays the status of current measurement
  • Help message as an operational guide, with quick access to test parameters
  • Conductivity/TDS Mode
  • 1 to 3 Conductivity push button calibration points
  • 3 TDS calibration points
  • 1 Temperature calibration point
Used to test Conductivity, TDS values of different type of liquid such as pure, hard/low conductivity water, distilled water. Also used in water purification labs, water testing and management plants, and water processing and packaging units for quality and research purpose
Accessories no. Name
1 Conductivity Electrode (range 0.01 to 20 mS/ cm)
2 Temperature Probe
3 Conductivity Calibration Standard Solutions
4 Electrode Holder
5 Power Adapter
Accessories no. Name
1 Conductivity Electrode (K=0.1) suitable for measuring the low conductivity liquids ( <10µS/ cm) e.g. Pure water
2 Conductivity Electrode (K=10) suitable for measuring the high conductivity liquids (>20mS/ cm) e.g. Sea water

pH Meter (Benchtop)

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

pH Meter (Benchtop) : Benchtop pH meter LBPM-A11

Benchtop pH meter LBPM-A11

  • pH measurement range
  • 0.00 to 14.00 pH
  • pH accuracy
  • ± 0.01 pH
  • pH resolution
  • 0.01 pH
pH Meter (Benchtop) : Benchtop pH meter LBPM-A20

Benchtop pH meter LBPM-A20

  • pH measurement range
  • -1.00 to 15.00 pH
  • pH accuracy
  • ± 0.01 pH
  • pH resolution
  • 0.01 pH
pH Meter (Benchtop) : Benchtop pH meter LBPM-B10
Benchtop pH meter LBPM-B10
  • pH measurement range
  • -2.000 to 20.000 pH
  • pH accuracy
  • ± 0.002 pH
  • Calibration points
  • 1-5 points
pH Meter (Benchtop) : Benchtop pH Meter LBPM-B11
Benchtop pH Meter LBPM-B11
  • Temperature compensation
  • 0 to 100°C, 32°F to 212°F Manual or Automatic
  • Hold function
  • Manual or automatic endpoint detection
  • Stability criteria
  • Standard or High-accuracy

Benchtop Conductivity Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Conductivity Meter : Benchtop conductivity meter LBCM-A11

Benchtop conductivity meter LBCM-A11

  • Conductivity measurement range
  • 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cm
  • Conductivity accuracy
  • ± 1 % F.S.
  • Conductivity resolution
  • 0.01, 0.1, 1
Benchtop Conductivity Meter : Benchtop Conductivity Meter LBCM-A13

Benchtop Conductivity Meter LBCM-A13

  • Conductivity measurement range
  • 0.000 μS/cm to 3000mS/cm
  • Resistivity measurement range
  • 5.00 Ω·cm to 100.0 MΩ·cm
  • TDS measurement range
  • 0.000 mg/L to 1000g/L

Benchtop Dissolved Oxygen Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Dissolved Oxygen Meter : Benchtop Dissolved oxygen meter LBDO-A10

Benchtop Dissolved oxygen meter LBDO-A10

  • Dissolved oxygen range
  • 0.0 to 20.0 mg / L (or ppm)
  • Dissolved oxygen accuracy
  • ± 0.5 mg / L
  • Resolution
  • 0.1 mg / L
Benchtop Dissolved Oxygen Meter : Benchtop Dissolved oxygen meter LBDO-A11

Benchtop Dissolved oxygen meter LBDO-A11

  • Dissolved oxygen range
  • 0.0 to 20.0 mg / L (or ppm)
  • Dissolved oxygen accuracy
  • ± 0.2 mg / L
  • Resolution
  • 0.01 mg / L

Benchtop Ion Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Ion Meter : Benchtop Ion meter for Cl, LBIM-A10

Benchtop Ion meter for Cl, LBIM-A10

  • Ion measurement range
  • Cl range: 5 × 106 - 1 M, 1.8 - 35500 ppm
  • Ion measurement accuracy
  • ± 0.5 % F.S.
  • Resolution
  • 0.001, 0.01, 0.1, 1
Benchtop Ion Meter : Benchtop Ion meter for F, LBIM-A11

Benchtop Ion meter for F, LBIM-A11

  • Ion measurement range
  • F range: 1 × 106M – saturation, 0.02 ppm to saturation
  • Ion measurement accuracy
  • ± 0.5 % F.S.
  • Resolution
  • 0.001, 0.01, 0.1, 1
Benchtop Ion Meter : Benchtop Ion meter for Na, LBIM-A12
Benchtop Ion meter for Na, LBIM-A12
  • Ion measurement range
  • Na range: 1 × 105 - 1 M, 0.1 - 23000 ppm
  • Ion measurement accuracy
  • ± 0.5 % F.S.
  • Resolution
  • 0.001, 0.01, 0.1, 1
Benchtop Ion Meter : Benchtop Ion meter for Ca, LBIM-A13
Benchtop Ion meter for Ca, LBIM-A13
  • Ion measurement range
  • Ca range: 5 × 107 - 1 M, 0.02 - 4000 ppm
  • Ion measurement accuracy
  • ± 0.5 % F.S.
  • Resolution
  • 0.001, 0.01, 0.1, 1

Conductivity Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

Conductivity Tester : Pocket Conductivity tester LPCT-A10

Pocket Conductivity tester LPCT-A10

  • Conductivity measurement range
  • 1.0 to 199.9 µS/cm
  • Type of conductivity
  • Low range conductivity
  • Conductivity accuracy
  • ± 1 % F.S.
Conductivity Tester : Pocket Conductivity tester LPCT-A11

Pocket Conductivity tester LPCT-A11

  • Conductivity measurement range
  • 10 to 1999 µS/cm
  • Type of conductivity
  • Mid-range conductivity
  • Conductivity accuracy
  • ± 1 % F.S.
Conductivity Tester : Pocket Conductivity tester LPCT-A12
Pocket Conductivity tester LPCT-A12
  • Conductivity measurement range
  • 0.1 to 19.99 mS/cm
  • Type of conductivity
  • High range conductivity
  • Conductivity accuracy
  • ± 1 % F.S.

ORP Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

ORP Tester : Pocket ORP tester LPOT-A10

Pocket ORP tester LPOT-A10

  • Sensor type
  • Platinum sensor
  • Connector
  • 6 pin
  • ORP measurement range
  • (-999) to 999 mV
ORP Tester : Pocket ORP tester LPOT-A11

Pocket ORP tester LPOT-A11

  • Connector
  • BNC
  • ORP measurement range
  • (-999) to 999 mV
  • ORP accuracy
  • ± 2 mV

pH Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

pH Tester : Pocket pH tester LPPT-A10

Pocket pH tester LPPT-A10

  • pH measurement range
  • 0.0 - 14.00 pH
  • Shape of electrode
  • Round glass pH electrode
  • pH measurement accuracy
  • ± 0.1 pH
pH Tester : Pocket pH tester LPPT-A11

Pocket pH tester LPPT-A11

  • pH measurement range
  • 0.0 - 14.00 pH
  • Shape of electrode
  • Flat pH electrode
  • pH measurement accuracy
  • ± 0.1 pH
pH Tester : Pocket pH tester LPPT-A12
Pocket pH tester LPPT-A12
  • pH measurement range
  • 0.0 - 14.00 pH
  • Shape of electrode
  • Long distance planar pH electrode
  • pH measurement accuracy
  • ± 0.1 pH
pH Tester : Pocket pH tester LPPT-A21
Pocket pH tester LPPT-A21
  • pH measurement range
  • pH range: (-1.00) to 15.00 pH
  • Shape of electrode
  • Flat pH electrode
  • pH measurement accuracy
  • ± 0.01 pH

Salinity Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

Salinity Tester : Pocket Salinity tester LPST-A10

Pocket Salinity tester LPST-A10

  • Salinity measurement range
  • 0.00 to 10.00 ppt
  • Salinity accuracy
  • ± 1 % F.S
  • Conductivity range
  • 0 - 20.00, 200.0, 2000 µS/cm, 20.00 mS/cm
Salinity Tester : Pocket Salinity tester LPST-A11

Pocket Salinity tester LPST-A11

  • Salinity measurement range
  • 0.00 to 80.00 ppt
  • Salinity accuracy
  • ± 1 % F.S
  • Conductivity range
  • 0 - 200.0 µS/cm, 100 - 2000 µS/cm, 20.00 mS/cm

TDS Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

TDS Tester : Pocket TDS tester LPTS-A10

Pocket TDS tester LPTS-A10

  • TDS range
  • 0.5 - 100.0 ppm
  • TDS accuracy
  • ± 1 % F.S.
  • TDS factor
  • 0.4 to 1.0 (default 0.5)
TDS Tester : Pocket TDS tester LPTS-A11

Pocket TDS tester LPTS-A11

  • TDS range
  • 5 - 1000 ppm
  • TDS accuracy
  • ± 1 % F.S.
  • TDS factor
  • 0.4 to 1.0 (default 0.5)
TDS Tester : Pocket TDS tester LPTS-A12
Pocket TDS tester LPTS-A12
  • TDS range
  • 0.05 - 10.00 ppt
  • TDS accuracy
  • ± 1 % F.S.
  • TDS factor
  • 0.4 to 1.0 (default 0.5)
TDS Tester : Multi-range pocket TDS tester LPTS-A20
Multi-range pocket TDS tester LPTS-A20
  • TDS range
  • 0 - 20 ppt
  • TDS accuracy
  • ± 1 % F.S.
  • TDS factor
  • 0.1 to 1.0 (default 0.5)

Portable Dissolve Oxygen Meter

Labtron portable meters are used in quality analysis of water and other solutions. With portability, waterproof features, finds applications in indoor as well as outdoor measurement of pH, ORP, dissolved oxygen, water hardness, salinity, TDS etc.

Portable Dissolve Oxygen Meter : Portable Dissolved oxygen meter LPRDO-A10

Portable Dissolved oxygen meter LPRDO-A10

  • Dissolved oxygen range
  • 0.0 to 20.0 mg / L (or ppm)
  • Dissolved oxygen accuracy
  • ± 0.5 mg / L
  • Resolution
  • 0.1 mg / L
Portable Dissolve Oxygen Meter : Portable dissolved oxygen meter LPRDO-A11

Portable dissolved oxygen meter LPRDO-A11

  • Dissolved oxygen range
  • 0.0 - 20.0 mg / L (or ppm)
  • Dissolved oxygen accuracy
  • ± 0.2 mg / L
  • Resolution
  • 0.01 mg / L

Portable Multi Parameter Water Quality Meter

Labtron portable meters are used in quality analysis of water and other solutions. With portability, waterproof features, finds applications in indoor as well as outdoor measurement of pH, ORP, dissolved oxygen, water hardness, salinity, TDS etc.

Portable Multi Parameter Water Quality Meter : Portable Multi-parameter Water Quality Meter LMPWM-A10

Portable Multi-parameter Water Quality Meter LMPWM-A10

  • pH mode
  • (-2.000) to 20.000 pH
  • ORP measurement
  • -1999.9 to 1999.9 mV
  • Ion measurement
  • 0 to 19999 ppm, mg/L, mol/L
Portable Multi Parameter Water Quality Meter : Portable Multi-parameter Water Quality Meter LMPWM-A11

Portable Multi-parameter Water Quality Meter LMPWM-A11

  • pH mode
  • (-2.000) to 20.000 pH
  • ORP measurement
  • -1999.9 to 1999.9 mV
  • Conductivity measurement
  • 0 - 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cm
Portable Multi Parameter Water Quality Meter : Portable Multi-parameter Water Quality Meter LMPWM-A20
Portable Multi-parameter Water Quality Meter LMPWM-A20
  • pH mode
  • (-2.000) to 20.000 pH
  • ORP measurement
  • -1999.9 to 1999.9 mV
  • Conductivity measurement
  • 0 - 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cm
Portable Multi Parameter Water Quality Meter : Portable Multi-parameter Water Quality Meter LMPWM-A21
Portable Multi-parameter Water Quality Meter LMPWM-A21
  • pH mode
  • (-2.000) to 20.000 pH
  • ORP measurement
  • -1999.9 to 1999.9 mV
  • Dissolved oxygen
  • 0.00 to 20.00 mg/L

pH Meters (Portable)

Labtron portable meters are used in quality analysis of water and other solutions. With portability, waterproof features, finds applications in indoor as well as outdoor measurement of pH, ORP, dissolved oxygen, water hardness, salinity, TDS etc.

pH Meters (Portable) : Portable pH meter LPRPM-A10

Portable pH meter LPRPM-A10

  • pH range
  • (-2.00) to 16.00 pH
  • pH accuracy
  • ± 0.01 pH
  • pH resolution
  • 0.01 pH
pH Meters (Portable) : Portable pH/ORP meter LPRPM-A11

Portable pH/ORP meter LPRPM-A11

  • pH range
  • (-2.00) to 20.00 pH
  • pH accuracy
  • ± 0.002 pH
  • pH resolution
  • 0.1, 0.01, 0.001 pH

Multi Parameter Water Quality Analyzer

Multi Parameter Water Quality Analyzer : Multi parameter water quality analyzer LMWA-A10

Multi parameter water quality analyzer LMWA-A10

  • COD
  • 2 to 10000 mg/ L
  • Ammonia nitrogen
  • 0.02 to 60 mg/ L
  • Total phosphorous
  • 0.002 to 20 mg/ L
Multi Parameter Water Quality Analyzer : Multi parameter water quality analyzer LMWA-A11

Multi parameter water quality analyzer LMWA-A11

  • COD
  • 5 to 5000 mg/ L
  • Ammonia nitrogen
  • 0.02 to 30 mg/ L
  • Total phosphorous
  • 0.002 to 10 mg/ L

Turbidity Meter

Turbidity Meter : Portable turbidity meter LTM-A16

Portable turbidity meter LTM-A16

  • Light source
  • LED/860 nm (Wavelength)
  • Readings display
  • LCD
  • Unit switches
  • NTU, FTU, EBC, ASBC
Turbidity Meter : Portable Turbidity Meter LTM-A10

Portable Turbidity Meter LTM-A10

  • Measuring range (NTU)
  • 0 to 200
  • Minimum readout value (NTU)
  • 0.1
  • Calibration point
  • Nil
Turbidity Meter : Portable Turbidity Meter LTM-A11
Portable Turbidity Meter LTM-A11
  • Measuring range (NTU)
  • 0 to 100, 0 to 200
  • Minimum readout value (NTU)
  • 0.01, 0.1
  • Calibration point
  • 4
Turbidity Meter : Portable Turbidity Meter LTM-A12
Portable Turbidity Meter LTM-A12
  • Measuring range (NTU)
  • 0 to 100, 100 to 400
  • Minimum readout value (NTU)
  • 0.01, 0.1
  • Calibration point
  • 5

Benchtop Multi-parameter Water Quality Meter

Benchtop Multi-parameter Water Quality Meter : Benchtop Multi-parameter Water Quality Meter LMPWM-A30

Benchtop Multi-parameter Water Quality Meter LMPWM-A30

  • pH Mode
  • pH range -2.00 to 20.00 pH pH Accuracy ± 0.002 pH pH Resolution 0.1/0.01/0.001 pH, selectable pH Calibration Points 1 to 5 Points pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
  • mV Mode
  • mV Range -1999.9 to 1999.9 mV mV Accuracy ± 0.2 mV mV Resolution 0.1/1 mV, selectable mV Calibration Points 1 Point
  • Conductivity Mode
  • Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm Conductivity Accuracy ± 0.5% F.S. Conductivity Resolution 0.01/0.1/1 Conductivity Calibration Points 1 to 5 Points Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm Conductivity Temperature coefficient 0.0 to 10.0 %/°C Compensation mode Linear or Pure Water Cell Constant K=0.1, 1, 10 or Custom Reference temperature 20 or 25°C
Benchtop Multi-parameter Water Quality Meter : Benchtop Multi-parameter Water Quality Meter LMPWM-A31

Benchtop Multi-parameter Water Quality Meter LMPWM-A31

  • pH Mode
  • pH range -2.00 to 20.00 pH pH Accuracy ± 0.002 pH pH Resolution 0.1/0.01/0.001 pH, selectable pH Calibration Points 1 to 5 Points pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
  • mV Mode
  • mV Range -1999.9 to 1999.9 mV mV Accuracy ± 0.2 mV mV Resolution 0.1/1 mV, selectable mV Calibration Points 1 Point
  • Conductivity Mode
  • Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm Conductivity Accuracy ± 0.5% F.S. Conductivity Resolution 0.01/0.1/1 Conductivity Calibration Points 1 to 5 Points Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm Conductivity Temperature coefficient 0.0 to 10.0 %/°C Compensation mode Linear or Pure Water Cell Constant K=0.1, 1, 10 or Custom Reference temperature 20 or 25°C
Benchtop Multi-parameter Water Quality Meter : Benchtop Multi-parameter Water Quality Meter LMPWM-A32
Benchtop Multi-parameter Water Quality Meter LMPWM-A32
  • pH Mode
  • pH range -2.00 to 20.00 pH pH Accuracy ± 0.002 pH pH Resolution 0.1/0.01/0.001 pH, selectable pH Calibration Points 1 to 5 Points pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
  • mV Mode
  • mV Range -1999.9 to 1999.9 mV mV Accuracy ± 0.2 mV mV Resolution 0.1/1 mV, selectable mV Calibration Points 1 Point
  • Conductivity Mode
  • Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm Conductivity Accuracy ± 0.5% F.S. Conductivity Resolution 0.01/0.1/1 Conductivity Calibration Points 1 to 5 Points Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm Conductivity Temperature coefficient 0.0 to 10.0 %/°C Compensation mode Linear or Pure Water Cell Constant K=0.1, 1, 10 or Custom Reference temperature 20 or 25°C
Benchtop Multi-parameter Water Quality Meter : Benchtop Multi-parameter Water Quality Meter LMPWM-A40
Benchtop Multi-parameter Water Quality Meter LMPWM-A40
  • pH Mode
  • pH range -2.00 to 20.00 pH pH Accuracy ± 0.002 pH pH Resolution 0.1/0.01/0.001 pH, selectable pH Calibration Points 1 to 5 Points pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
  • ORP Mode
  • mV Range ± 2000 mV mV Accuracy ± 0.2 mV mV Resolution 0.1 mV, selectable mV Calibration Points 1 Point, only for relative mode
  • Ion Mode
  • Ion measurement range 0.01 to 30000 ppm, mg/l, mol/l, mmol/l (refer Range of ion selection) Ion measurement accuracy ±0.5% F.S (Monovalent), ±1% F.S (Divalent) Ion measurement resolution 0.001/0.01/0.1/1 Ion measurement calibration points 2 to 5 points Ion measurement calibration solutions 0.001/0.01/0.1/1/10/100/1000/10000 ppm, mg/L, mol/L Ion measurement methods Direct reading, Known addition, Known subtraction, Sample addition, Sample subtraction

Portable Conductivity Meter

Portable Conductivity Meter : Portable Conductivity Meter LPCM-A10

Portable Conductivity Meter LPCM-A10

  • Conductivity
  • 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cm
  • Temperature
  • 0 105 °C, 32 to 221 °F
  • Temperature compensation
  • 0 to 100 °C, 32 to 212 ° F, Manual or Automatic
Portable Conductivity Meter : Portable Conductivity Meter LPCM-A11

Portable Conductivity Meter LPCM-A11

  • Conductivity
  • 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cm
  • TDS
  • 0 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)
  • Temperature
  • 0 105 °C, 32 to 221 °F
Portable Conductivity Meter : Portable Conductivity Meter LPCM-A12
Portable Conductivity Meter LPCM-A12
  • Conductivity
  • 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cm
  • Salinity
  • 0.00 to 80.00 ppt, 0.00 to 42.00 psu
  • Temperature
  • 0 105 °C, 32 to 221 °F
Portable Conductivity Meter : Portable Conductivity Meter LPCM-A13
Portable Conductivity Meter LPCM-A13
  • Conductivity
  • 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cm
  • TDS
  • 0 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)
  • Salinity
  • 0.00 to 80.00 ppt, 0.00 to 42.00 psu

Water Activity Meter

Water Activity Meter : Water Activity Meter LWTM-A10

Water Activity Meter LWTM-A10

  • Range
  • 0 to 1.0 aw
  • Resolution
  • 0 to 1.0 aw
  • Accuracy
  • ± 0.02 aw
Water Activity Meter : Water Activity Meter with sensor LWAM-A10

Water Activity Meter with sensor LWAM-A10

  • Measuring range
  • Water activity 0 to 0.980 aw (no condensing )
  • Temperature range
  • 0 to 50°C
  • Measurement accuracy
  • ± 0.015 aw