Request Quote Form
pH measurement range | (-2.000) to 20.000 pH |
pH accuracy | ± 0.002 pH |
pH calibration points | 1 - 5 points |
pH calibration solutions | USA, NIST, DIN or user defined |
ORP measurement range | -1999.9 to 1999.9 mV |
ORP accuracy | ±0.2 mV |
ORP calibration points | 1 point |
ORP calibration solutions | mV & relative mV |
Ion measurement range | 0 to 19999 ppm, mg/L, mol/L |
Ion accuracy | ± 0.5 % F.S. (monovalent), ± 1 % F.S. (divalent) |
Ion calibration points | 2 - 5 points |
Ion calibration solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol/L, mg/L |
Conductivity measurement range | 0 - 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cm |
Conductivity accuracy | ± 0.5 % F.S. |
Conductivity calibration points | 1 - 5 points |
Conductivity calibration solutions | 10 µS / cm, 84 µS / cm, 1413 µS / cm, 12.88mS / cm, 111.8mS / cm |
pH measurement range | (-2.000) to 20.000 pH |
pH accuracy | ± 0.002 pH |
pH calibration points | 1 - 5 points |
pH calibration solutions | USA, NIST, DIN or user defined |
ORP measurement range | -1999.9 to 1999.9 mV |
ORP accuracy | ±0.2 mV |
ORP calibration points | 1 point |
ORP calibration solutions | mV & relative mV |
Conductivity measurement range | 0 - 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cm |
Conductivity accuracy | ± 0.5 % F.S. |
Conductivity calibration points | 1 - 5 points |
Conductivity calibration solutions | 10 µS / cm, 84 µS / cm, 1413 µS / cm, 12.88mS / cm, 111.8mS / cm |
pH measurement range | (-2.000) to 20.000 pH |
pH accuracy | ± 0.002 pH |
pH calibration points | 1 - 5 points |
pH calibration solutions | USA, NIST, DIN or user defined |
ORP measurement range | -1999.9 to 1999.9 mV |
ORP accuracy | ±0.2 mV |
ORP calibration points | 1 point |
ORP calibration solutions | mV & relative mV |
Conductivity measurement range | 0 - 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cm |
Conductivity accuracy | ± 0.5 % F.S. |
Conductivity calibration points | 1 - 5 points |
Conductivity calibration solutions | 10 µS / cm, 84 µS / cm, 1413 µS / cm, 12.88mS / cm, 111.8mS / cm |
TDS range | 0-100 ppt. (max. 200 ppt., depending on factor setting) |
TDS accuracy | ± 1 % F.S. |
TDS factor | 0.1 - 1.0 (default 0.5) |
pH measurement range | (-2.000) to 20.000 pH |
pH accuracy | ± 0.002 pH |
pH calibration points | 1 - 5 points |
pH calibration solutions | USA, NIST, DIN or user defined |
ORP measurement range | -1999.9 to 1999.9 mV |
ORP accuracy | ±0.2 mV |
ORP calibration points | 1 point |
ORP calibration solutions | mV & relative mV |
DO concentration range | 0.00 to 20.00 mg/L |
DO accuracy | ± 0.2 mg/L |
Calibration points | 1 - 2 points |
Pressure correction | 60.0 to 112.5 kPa, 450 - 850 mmHg |
Popular Products
Navigation
Contact Us Map