ICP Spectrometer : ICP spectrometer LICP-A10


Share :


Wavelength range ( 3600 lines / mm )180 to 500 nm
Wavelength range ( 2400 lines / mm )180 to 800 nm
Temperature20 ~ 28 °C
Elements per minute26 elements
Humidity70%
Focal length1000 mm
Standard deviationRSD ≤ 1.0 %
Correlation coefficient≥ 0.9998
Gas sourceArgon ( 99.99 % )
Plasma gas flow meter100 ~ 1000 L / h
Auxillary gas flow meter10 ~ 100 L / h
Carrier gas flow meter10 ~ 100 L / h
Cooling water flow rate5 liters per min
Cooling water temperature21 ~ 26 °C
Water outlet diameterØ 10 mm
Line dispersion rate0.26 nm
Resolving power≤ 0.008 nm
Incident slit20 µm
Co-axial sprayer diameter6 mm
Coil diameter25 mm ( 3 turn )
Double room fog diameter34 mm
Quartz tube torch diameter20 mm
Mirror dimensions78 x 105 x 16 mm
  • Scanning range variance ( 190 nm to 500 nm / 190 nm to 800 nm )
  • Rapid analysis – 26 elements per minute
  • Temperature range – 20 to 28 °C
  • Optical pathway – Czerny-turners
  • Low detection limit
  • Detection of multi-elements including non-metallic
  • Single and multi-element measurement method
  • Indication for wavelength error and repeatability
  • Range of measurement – common to trace
Element Be Mg Ca Sr Ba Sc Y Eu Yb
Wavelength ( nm ) 313.042 279.553 393.366 407.771 455.403 335.373 371.03 381.967 369.419
Detection limit < 1.0 < 1.0 < 1.0 < 1.0 < 1.0 < 1.0 < 1.0 < 1.0 < 1.0
Element Lu La Gd Dy Ho Er Tm Zn Cd
Wavelength ( nm ) 261.542 333.749 342.247 353.17 345.6 337.271 313.126 213.856 226.502
Detection limit < 1.0 < 3.0 < 3.0 < 3.0 < 3.0 < 3.0 < 3.0 < 3.0 < 3.0
Element Fe Ti Cu Mn V B Ni Cr Co
Wavelength ( nm ) 239.562 344.941 324.754 257.61 309.311 249.773 221.647 205.552 238.204
Detection limit < 3.0 < 3.0 < 3.0 < 3.0 < 3.0 < 5.0 < 5.0 < 5.0 < 5.0
Element Zr Mo Ag Au Si Al Ir P Hg
Wavelength ( nm ) 343.823 202.03 328.068 242.795 251.611 396.152 224.268 213.618 194.227
Detection limit < 5.0 < 5.0 < 5.0 < 5.0 < 5.0 < 10.0 < 10.0 < 10.0 < 10.0
Used in clinical analysis for detection of metals in biological fluids , environmental analysis for trace element detection in water , soil , plants , pharmaceuticals for traces of catalysts and poison metals like Cd , Pb , industries for noble metal detection

ICP Spectrometer

ICP Spectrometer : ICP Spectrometer LICP-A11

ICP Spectrometer LICP-A11

  • Wavelength range
  • 180 to 900 nm
  • Elements per minute
  • 15 elements
  • Temperature
  • 29 °C
ICP Spectrometer : ICP Spectrometer LICP-B10

ICP Spectrometer LICP-B10

  • Monochromator Specifications
  • Czerny turner
  • Solid State Power Specifications
  • 27.12 MHz Frequency stability: < 0.05%
  • Technical Specifications
  • Liquid sample: 0.01 ppm to several thousand ppm Solid or power sample: 0.001% to 70%

XRF Spectrometer

XRF Spectrometer : XRF-Spectrometer LXRF-A10

XRF-Spectrometer LXRF-A10

  • Measureable elements
  • S to U
  • Detection limit
  • 1 ppm
  • Temperature
  • 15 ~ 30 °C
XRF Spectrometer : Handheld XRF Spectrometer LXRF-B10

Handheld XRF Spectrometer LXRF-B10

  • Analytical Method
  • Energy dispersive X-ray fluorescence analytical Method
  • Elements Measuring
  • Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measured
  • Range
  • Simultaneous detector
XRF Spectrometer : Handheld XRF Spectrometer LXRF-B11
Handheld XRF Spectrometer LXRF-B11
  • Analytical Method
  • Energy dispersive X-ray fluorescence analytical Method
  • Elements Measuring
  • Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measured
  • Range
  • Simultaneous detector