Visible Spectrophotometer : Visible Spectrophotometer LVS-A30


Share :



Visible Spectrophotometer LVS-A30 is single beam, blazed holographic optical system with 320 to 1100 nm wavelength range, and offers spectral bandwidth of 2.0 nm. Designed with Large LCD display (128 × 64 Dots), it display curve and high quality grating, detector and lamps. Features with T, A, C work mode and Tungsten lamp & Deuterium lamp (Pre-aligned). Designed with holographic blazed grating monochromator has the advantages of high wavelength accuracy, good monochromaticity and low stray light. It offers high accuracy, good reproducibility and stability of measurement reading instrument.



Available Range :

Wavelength Range : 330 to 1000 nm Wavelength Range : 335 ~ 1000 nm Wavelength Range : 325 ~ 1000 nm Wavelength Range : 320 ~ 1100 nm Wavelength Range : 320 ~ 1000 nm Wavelength range : 320 to 1100 nm
Wavelength range320 to 1100 nm
Spectral bandwidth2.0 nm
Wavelength Accuracy± 0.8 nm
Wavelength Repeatability≤ 0.3 nm
Optical systemSingle beam, blazed holographic Grating (1200 lines/mm)
Photometric Range0 to 200 %T, -0.3 to 3 A, 0 to 9999 C
Photometric Accuracy± 0.002A (0 to 0.5A), ±0.004 A (0.5 to 1A), ±0.5 % T (0 to 100% T)
Photometric Repeatability≤ 0.001A (0 to 0.5 A), ≤0.002A (0.5 to 1A), ≤0.2 % T (0 to 100% T)
DetectorSilicon Photocell
Stray light≤ 0.1% T (220/360 nm)
Noise≤0.2 % T/3 min (250/500 nm, 0% T), ≤ 0.5% T/3 min (250/500 nm, 100% T)
Scan speedHigh, Medium, Low, Max. 2000 nm/minute
Baseline flatness± 0.003 A
Stability± 0.002 A/h (500 nm, 0A)
Sample compartmentAccommodates 5 to 100 nm Path length cuvette
LampsTungsten lamp & Deuterium lamp (Pre-aligned)
DisplayGraphic LCD (128 × 64 Dots)
Keyboard22 key Numeric membrane keyboard
Output PortUSB Port & RS232 Port
PrinterMini Serial Printer, PC printer
PC softwareOptional PC scanning software
Dimension490 × 390 × 280 mm
Power supplyAC 90 to 250 V, 50/60 Hz
Gross weight16 kg
  • The holographic blazed grating monochromator has the advantages of high wavelength accuracy, good monochromaticity and low stray light
  • Designed with Large LCD display (128 × 64 Dots)
  • Sample compartment accommodates 5 to 100 nm Path length cuvette
  • Equipped with USB Port and RS232 Port
  • Auto setting WL, auto Blank
  • Lamps can be turned on/off individually
  • Adopts microprocessor control technology, qualitative analysis of substances in the visible spectrum, High accuracy of measurement readings, good stability
  • Automatic light gate technology, no need blackbody, to protect the photoelectric sensor
  • Reinforced baseboard and bracket assures durability
Visible Spectrophotometer is used in high requirement for precision measurement in the research and production of organic chemistry, biochemistry, medical testing, food testing, environmental protection, water testing industries, etc.

Double Beam UV/Vis Spectrophotometer

Our range of Double Beam UV/VIS spectrophotometers offer long optical path which ensure high accuracy and stability. Its design measures the transmittance of the sample and solvent simultaneously. It is highly precise and performs powerful analysis.

Double Beam UV/Vis Spectrophotometer : Double Beam UV/Vis Spectrophotometer LUS-B16

Double Beam UV/Vis Spectrophotometer LUS-B16

  • Wavelength Range
  • 190 ~ 1100 nm
  • Setting Wavelength
  • Automatic
  • Spectral Bandwidth
  • 0.5 / 1.0 / 2.0 / 4.0 nm adjustable
Double Beam UV/Vis Spectrophotometer : Double beam UV-Visible Spectrophotometer LUS-B14

Double beam UV-Visible Spectrophotometer LUS-B14

  • Wavelength range
  • 190 ~ 1100 nm
  • Spectral bandwidth
  • 1.8 nm
  • Wavelength accuracy
  • ± 0.3 nm
Double Beam UV/Vis Spectrophotometer : Double Beam UV/Vis Spectrophotometer LUS-B30
Double Beam UV/Vis Spectrophotometer LUS-B30
  • Wavelength range
  • 190 to 1100 nm
  • Spectral bandwidth
  • 2 nm
  • Wavelength Accuracy
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Double Beam UV/Vis Spectrophotometer : Double Beam UV/Vis Spectrophotometer LUS-B31
Double Beam UV/Vis Spectrophotometer LUS-B31
  • Wavelength range
  • 190 to 1100 nm
  • Spectral bandwidth
  • 1 nm
  • Wavelength Accuracy
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all

Nano Spectrophotometer

We produce a wide range of Nano spectrophotometer for qualitative and quantitative analysis of DNA/RNA in the sample. Our product is highly sensitive and requires only 0.5-2µl of sample for analysis.

Nano Spectrophotometer : Nano Spectrophotometer LNS-A10

Nano Spectrophotometer LNS-A10

  • Wavelength range
  • 200 - 800 nm
  • Path length
  • 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary)
  • Wavelength accuracy
  • ± 1 nm
Nano Spectrophotometer : Nano Spectrophotometer LNS-A21

Nano Spectrophotometer LNS-A21

  • Wavelength range
  • 200 - 850 nm
  • Path length
  • 1 mm, 2 mm, 5 mm, 10 mm
  • Wavelength accuracy
  • ± 1 nm
Nano Spectrophotometer : Nano Spectrophotometer LNS-B11
Nano Spectrophotometer LNS-B11
  • Wavelength range
  • 230 nm, 260 nm, 280 nm
  • Path length
  • 1.0 mm, 0.2 mm
  • Minimum Sample size
  • 0.3 - 2.0 µl
Nano Spectrophotometer : Nano Spectrophotometer LNS-C10
Nano Spectrophotometer LNS-C10
  • Cuvette
  • No
  • PC
  • Inbuilt
  • Wavelength range
  • 190 - 850 nm

Single Beam UV/Visible Spectrophotometer

We manufacture highly precise UV/Vis automatic scanning spectrophotometer with wavelength ranging from 190-1100nm. It can perform quantitative measurement, photometric measurement, spectrum scanning, DNA/Protein analysis. It is in demand for its user-friendly operations

Single Beam UV/Visible Spectrophotometer : Single Beam UV/Visible Spectrophotometer LUS-A10

Single Beam UV/Visible Spectrophotometer LUS-A10

  • Wavelength Range
  • 190 ~ 1100 nm
  • Spectral Bandwidth
  • 1 nm
  • Wavelength Accuracy
  • ± 0.3 nm
Single Beam UV/Visible Spectrophotometer : Single Beam UV/Visible Spectrophotometer LUS-A11

Single Beam UV/Visible Spectrophotometer LUS-A11

  • Wavelength Range
  • 190 ~ 1100 nm
  • Spectral Bandwidth
  • 1.8 nm
  • Wavelength Accuracy
  • ± 0.3 nm
Single Beam UV/Visible Spectrophotometer : Single Beam UV/Visible Spectrophotometer LUS-A20
Single Beam UV/Visible Spectrophotometer LUS-A20
  • Wavelength Range
  • 190 ~ 1100 nm
  • Setting Wavelength
  • Automatic
  • Spectral Bandwidth
  • 2 nm
Single Beam UV/Visible Spectrophotometer : Single Beam UV/Visible Spectrophotometer LUS-A21
Single Beam UV/Visible Spectrophotometer LUS-A21
  • Wavelength Range
  • 190 ~ 1100 nm
  • Setting Wavelength
  • Automatic
  • Spectral Bandwidth
  • 1.8 nm

Visible Spectrophotometer

Labtron provides extensive range of visible spectrophotometer LVS series which can operate over a wavelength range of 320-1100nm. It brings unmatched performance with outstanding accuracy and precision.

Visible Spectrophotometer : Vis Spectrophotometer LVS-A10

Vis Spectrophotometer LVS-A10

  • Wavelength Range
  • 330 to 1000 nm
  • Spectral Bandwidth
  • 5 nm
  • Wavelength Accuracy
  • ± 2 nm
Visible Spectrophotometer : Vis Spectrophotometer LVS-A11

Vis Spectrophotometer LVS-A11

  • Wavelength Range
  • 335 ~ 1000 nm
  • Spectral Bandwidth
  • 4 nm
  • Wavelength Accuracy
  • ± 2 nm
Visible Spectrophotometer : Vis Spectrophotometer LVS-B10
Vis Spectrophotometer LVS-B10
  • Wavelength Range
  • 325 ~ 1000 nm
  • Setting Wavelength
  • Automatic
  • Spectral Bandwidth
  • 2 nm
Visible Spectrophotometer : Vis Spectrophotometer LVS-C10
Vis Spectrophotometer LVS-C10
  • Wavelength Range
  • 320 ~ 1100 nm
  • Spectral Bandwidth
  • 4 nm
  • Wavelength Accuracy
  • ± 0.5 nm

Atomic Absorption Spectrophotometer

Labtron Atomic Absorption Spectrophotometer makes use of the modern in technology. It is acquired after thorough research into the desires of the diagnostic community. It has all the power, performance and speed necessitated in today’s modern laboratory.

Atomic Absorption Spectrophotometer : Atomic Absorption Spectrophotometer LAAS-A11

Atomic Absorption Spectrophotometer LAAS-A11

  • Wavelength range
  • 190 - 900 nm
  • Spectral Bandwidth
  • 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm
  • Wavelength accuracy
  • ≤ ± 0.5 nm
Atomic Absorption Spectrophotometer : Atomic Absorption Spectrophotometer LAAS-A20

Atomic Absorption Spectrophotometer LAAS-A20

  • Wavelength range
  • 180 - 900 nm
  • Spectral Bandwidth
  • 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting)
  • Wavelength accuracy
  • ≤ 0.15 nm
Atomic Absorption Spectrophotometer : Atomic Absorption Spectrophotometer LAAS-A21
Atomic Absorption Spectrophotometer LAAS-A21
  • Wavelength range
  • 180 – 900 nm
  • Spectral Bandwidth
  • 0 nm, 0.2 nm, 0.4 nm, 1.0 nm, 2.0 nm (5 steps with automatic changeover)
  • Wavelength accuracy
  • ≤ 0.15 nm
Atomic Absorption Spectrophotometer : Atomic Absorption Spectrophotometer LAAS-A22
Atomic Absorption Spectrophotometer LAAS-A22
  • Wavelength range
  • 180 – 900 nm
  • Spectral Bandwidth
  • 0.1 nm,0.2 nm,0.4 nm, 1.0 nm, 2.0 nm automatic setting
  • Wavelength accuracy
  • ≤ 0.15 nm

Table Top Spectrophotometer

Table Top Spectrophotometer : Table top spectrophotometer LTS-A10

Table top spectrophotometer LTS-A10

  • Illumination system
  • d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Size of integrated sphere
  • 40 mm, alvan diffused reflection surface coating
  • Illumination light source
  • CLED
Table Top Spectrophotometer : Table top spectrophotometer LTS-A11

Table top spectrophotometer LTS-A11

  • Illumination system
  • d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Size of integrated sphere
  • 40 mm, alvan diffused reflection surface coating
  • Illumination light source
  • CLED
Table Top Spectrophotometer : Table top spectrophotometer LTS-A12
Table top spectrophotometer LTS-A12
  • Illumination system
  • d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Size of integrated sphere
  • 15.2 cm, alvan diffused reflection surface coating
  • Illumination light source
  • CLED
Table Top Spectrophotometer : Table top spectrophotometer LTS-A13
Table top spectrophotometer LTS-A13
  • Illumination system
  • d/0 (Diffused lighting, 0° observation viewing), SCS optical engine (light splitting and integration system), ETC (every time calibration technology), SCI (specular reflection included)/ SCE (specular reflection excluded) simultaneous measurement
  • Size of integrated sphere
  • 40 mm, alvan diffused reflection surface coating
  • Illumination light source
  • CLED

Portable Spectrophotometer

Portable Spectrophotometer : Portable spectrophotometer LSP-A10

Portable spectrophotometer LSP-A10

  • Illumination
  • d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Repeatability
  • Light splitting reflectivity:standard deviation within 0.08% Color values:ΔE*ab
  • Sensor
  • Blue light enhanced sensor array
Portable Spectrophotometer : Portable spectrophotometer LSP-A11

Portable spectrophotometer LSP-A11

  • Illumination
  • d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Repeatability
  • Light splitting reflectivity:standard deviation within 0.08% Color values:ΔE*ab Maximum:0.03
  • Sensor
  • Dual light path sensor array
Portable Spectrophotometer : Portable spectrophotometer LSP-A12
Portable spectrophotometer LSP-A12
  • Illumination
  • d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Repeatability
  • Light splitting reflectivity:standard deviation within 0.08% Color values:ΔE*ab
  • Sensor
  • Photoelectric diode sensor
Portable Spectrophotometer : Portable spectrophotometer LSP-A13
Portable spectrophotometer LSP-A13
  • Illumination
  • d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Repeatability
  • Light splitting reflectivity:standard deviation within 0.08% Color values:ΔE*ab
  • Sensor
  • Photoelectric diode sensor

Fluorescence Spectrophotometer

Fluorescence Spectrophotometer : Fluorescence Spectrophotometer LFS-A10

Fluorescence Spectrophotometer LFS-A10

  • Light source
  • 150 W Xenon lamp
  • Excitation wavelength
  • 200 nm to 900 nm
  • Emission wavelength
  • 200 nm to 900 nm
Fluorescence Spectrophotometer : Fluorescence Spectrophotometer LFS-A12

Fluorescence Spectrophotometer LFS-A12

  • Light source
  • 150 W Xenon lamp
  • Excitation wavelength
  • 200 nm to 900 nm
  • Emission wavelength
  • 200 nm to 900 nm
Fluorescence Spectrophotometer : Fluorescence Spectrophotometer LFS-A11
Fluorescence Spectrophotometer LFS-A11
  • Excitation Source
  • 150 W Xenon Lamp
  • Excitation Wavelength
  • 200 nm to 900 nm
  • Excitation Slit
  • 1 nm, 2 nm, 5 nm, 10 nm, 20 nm

Xenon Lamp Spectrophotometer

Xenon Lamp Spectrophotometer : Xenon Lamp Spectrophotometer LXLS-A10

Xenon Lamp Spectrophotometer LXLS-A10

  • Optical system
  • Double Beam, Grating 1200 lines/mm
  • Wavelength Range
  • 190 nm to 1100 nm
  • Spectral Bandwidth
  • 2 nm
Xenon Lamp Spectrophotometer : Xenon Lamp Spectrophotometer LXLS-A11

Xenon Lamp Spectrophotometer LXLS-A11

  • Optical system
  • Double Beam, Grating 1200 lines/mm
  • Wavelength Range
  • 190 nm to 1100 nm
  • Spectral Bandwidth
  • 1 nm
Xenon Lamp Spectrophotometer : Xenon Lamp Spectrophotometer LXLS-A13
Xenon Lamp Spectrophotometer LXLS-A13
  • Optical system
  • Double Beam, Grating 1200 lines/mm
  • Wavelength Range
  • 190 nm to 1100 nm
  • Spectral Bandwidth
  • 2 nm
Xenon Lamp Spectrophotometer : Xenon Lamp Spectrophotometer LXLS-A14
Xenon Lamp Spectrophotometer LXLS-A14
  • Optical system
  • Double Beam, Grating 1200 lines/mm
  • Wavelength Range
  • 190 nm to 1100 nm
  • Spectral Bandwidth
  • 1 nm