Atomic Absorption spectrophotometer comes with flame, graphite furnace and hydride generation system to meet different customer demand. It is provided with deuterium hollow cathode lamp to eliminate the interference of molecular absorption and Titanium Burner to improve the analysis efficiency and accuracy of the flame. The autosampler has integrated graphite furnace design with high-precision syringes to enter volume as minimum as 0.5μl with intelligent online dilution and concentration function. It has great applications research and medicine, environmental science and other industries.
Available Range :
Wavelength range : 190 - 900 nm Wavelength range : 180 - 900 nm Wavelength range : 180 – 900 nm Wavelength range : 180 – 900 nm Wavelength range : 190 nm ~ 900 nm Working spectral range : 190 to 900 nmWavelength range | 180 – 900 nm |
Spectral Bandwidth | 0.1 nm,0.2 nm,0.4 nm, 1.0 nm, 2.0 nm automatic setting |
Wavelength accuracy | ≤ 0.15 nm |
Wavelength repeatability | ± 0.1 nm |
Baseline drift | ≤ ± 0.002 Abs/30 min (Static) ≤ ± 0.005 Abs/30 min (Dynamic) |
Sample Volume | 1 - 100 μl |
The volume of sample | better than 1 %(at the time of 10 mL - 100 mL) |
Repeated Sampling Frequency | up to 99 Times |
Cleaning and waste container volume | Each 500 mL |
Absorbance Range | 0 - 4 A |
The Program | Automatic temperature control up to 20 order |
Temperature Range | room temperature to 3000 ℃ |
Detector | imported photomultiplier tube |
Heating Mode | vertical heating |
Temperature Control Method | Vertical optical temperature monitoring graphite tube wall temperature |
Temperature Control | The furnace enriched up to 20 times |
Lamp holder | ≤ 6 lamps automatic turret, automatic alignment |
Lamp power supply mode | pulsed power supply |
Optical System | Large 1800 /mm grating ruling, full closed optical system |
Atomization Chamber | Polymer explosion-proof spray chamber |
Characteristics Volume | 0.5 × 10-12g (Cd) |
Characteristic concentration (Cu) | 0.015 μg / mL / 1 % |
Detection Limit | 0.4 × 10-12g (Cd) |
Detection Limit (Cu) | 0.002 μg/mL |
Burner | Full titanium combustion head, 50 mm or 100 mm general combustion head |
Nebulizer | Atomizer efficient glass atomizer,can also be customized |
Precision | RSD ≤ 0.5 |
Ignition Type | Microcomputer control, automatic ignition |
Sample Tray | 70 sample cups, 6 reagent cup |
The Smallest Lincrement | 0.1 μl |
Safety measures | The graphite tube damage, water flow Air pressure and other alarm temperature overheating protection |
Gas Control | Automatic gas control system |
Measurement | Flame method, Hydride generation-Atomic absorption method |
Concentration calculation | Standard curve method(1 - 3 times curve), automatic fitting |
The Cooling Water | Can choose cooling water circulation system |
The number of repeated measurements | 1 to 99, automatic calculation of average concentration, standard deviation, relative standard deviation. |
Print results | Print the final stages of test data or analysis. The results can be exported into Excel worksheet. |
Power supply | 110 / 220 V (+5 % ~ (-10) %), 60 / 50 Hz; 5000 VA |
Our range of Double Beam UV/VIS spectrophotometers offer long optical path which ensure high accuracy and stability. Its design measures the transmittance of the sample and solvent simultaneously. It is highly precise and performs powerful analysis.
We produce a wide range of Nano spectrophotometer for qualitative and quantitative analysis of DNA/RNA in the sample. Our product is highly sensitive and requires only 0.5-2µl of sample for analysis.
We manufacture highly precise UV/Vis automatic scanning spectrophotometer with wavelength ranging from 190-1100nm. It can perform quantitative measurement, photometric measurement, spectrum scanning, DNA/Protein analysis. It is in demand for its user-friendly operations
Labtron provides extensive range of visible spectrophotometer LVS series which can operate over a wavelength range of 320-1100nm. It brings unmatched performance with outstanding accuracy and precision.
Labtron Atomic Absorption Spectrophotometer makes use of the modern in technology. It is acquired after thorough research into the desires of the diagnostic community. It has all the power, performance and speed necessitated in today’s modern laboratory.
Popular Products
Navigation
Contact Us Map