Transmitted spectrophotometer LTS-A13 with table top design is used to measure the transmittance, absorbency, concentration as well as reflectance of the material. Equipped with SCS system for best measurement repeatability & accurate measurement of surface color of material. The double grating & double optical path splitting system & ETC (every test calibration technology) produces 0.01% resolution, color balance intensity across visible spectrum & highly accurate measurements.



Available Range :

Illumination system : d/8 (Diffused lighting, 8° observation angle)
SCS optical engine (light splitting and integration system)
ETC (real time calibration technology )
SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
Illumination system : d/8 (Diffused lighting, 8° observation angle)
SCS optical engine (light splitting and integration system)
ETC (real time calibration technology )
SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
Illumination system : d/8 (Diffused lighting, 8° observation angle)
SCS optical engine (light splitting and integration system)
ETC (real time calibration technology )
SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
Illumination system : d/0 (Diffused lighting, 0° observation viewing), SCS optical engine (light splitting and integration system), ETC (every time calibration technology), SCI (specular reflection included)/ SCE (specular reflection excluded) simultaneous measurement Wavelength Range : 400 nm to 700 nm Wavelength Range : 360 nm to 780 nm
Illumination systemd/0 (Diffused lighting, 0° observation viewing), SCS optical engine (light splitting and integration system), ETC (every time calibration technology), SCI (specular reflection included)/ SCE (specular reflection excluded) simultaneous measurement
Size of integrated sphere40 mm, alvan diffused reflection surface coating
Illumination light sourceCLED
SensorDual light path sensor array
Light sourceA, C, D50, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, DLF, TL183, TL184, NBF, U30, CWF
Wavelength range400-700 nm
Wavelength interval10 nm
Half spectral width5 nm
Reflectivity range & resolution0 to 200%, 0.01%
Observation Angle2°/10°
Measurement time interval0.5 s
Measurement time2 s
Measuring aperture25.5*10 mm (cuvette support)
Color spaceCIE-L*a*b, L*C*h, L*u*v, XYZ, Yxy, Transmittance, Hunterlab, Munsell Mi, CMYK
Color difference formulaΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*94,ΔE*00,ΔEab(Hunter),555 color classification
Other colorimetric indicesWI (whiteness) (ASTM E313-10,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger,Ganz, Stensby)
YI (yellowness) (ASTM D1925,ASTM E313-00,ASTM E313-73), Tint(ASTM E313,CIE,Ganz)
Metamerism index Milm, staining fastness, color fastness, APHA, Astm color, ISO illuminance, saybolt
RepeatabilityTransmittance: standard deviation within 0.08%
color values:ΔE*ab<=0.015
(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),Maximum:0.03
Work temperature range0-45°C, relative humidity 80% or below (at 35°C), no condensation
Storage temperature range25℃ to 55℃ relative humidity 80% or below(at 35°C ),no condensation
Data being displayedSample's color values,color difference values/graph,pass/fail results,color error tendency,color value simulation, color difference values, display measurement area,history data color simulation,manual input standard sample, generate measurement report
InterfaceUSB
Data storageMass storage (on PC)
Light source longevity5 years, 1.5 million tests
Dimension (L*W*H)475 × 340 × 150 mm
Weight7 kg
  • D/0 Diffused lighting illumination system
  • CLED light source to guarantee the measurement speed & test accuracy
  • 1.5 ml sample volume
  • Double grating & double optical path splitting system
  • SCI & SCE both includes lightening & observation conditions
  • Connection to PC data storage , transmission
  • UV enhanced silicon photodiode with up to 200% improved transmittance range
  • ETC to ensure reliability & accuracy in every test measurement
  • Performs glass and liquid color measurement
Transmittance spectrophotometer is used in the measurement of range of liquids and solvents like resins, solvents, oils etc. to be used in food, chemical, textile, life science industries.
Accessories No. Name
1 Power cord
2 USB cable
3 Driving software
4 Color QC software
5 Black and white calibration tile

Double Beam UV/Vis Spectrophotometer

Our range of Double Beam UV/VIS spectrophotometers offer long optical path which ensure high accuracy and stability. Its design measures the transmittance of the sample and solvent simultaneously. It is highly precise and performs powerful analysis.

Double Beam UV/Vis Spectrophotometer : Double Beam UV/Vis Spectrophotometer LUS-B16

Double Beam UV/Vis Spectrophotometer LUS-B16

  • Wavelength Range
  • 190 ~ 1100 nm
  • Setting Wavelength
  • Automatic
  • Spectral Bandwidth
  • 0.5 / 1.0 / 2.0 / 4.0 nm adjustable
Double Beam UV/Vis Spectrophotometer : Double beam UV-Visible Spectrophotometer LUS-B14

Double beam UV-Visible Spectrophotometer LUS-B14

  • Wavelength range
  • 190 ~ 1100 nm
  • Spectral bandwidth
  • 1.8 nm
  • Wavelength accuracy
  • ± 0.3 nm
Double Beam UV/Vis Spectrophotometer : Double Beam UV/Vis Spectrophotometer LUS-B30
Double Beam UV/Vis Spectrophotometer LUS-B30
  • Wavelength range
  • 190 to 1100 nm
  • Spectral bandwidth
  • 2 nm
  • Wavelength Accuracy
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Double Beam UV/Vis Spectrophotometer : Double Beam UV/Vis Spectrophotometer LUS-B31
Double Beam UV/Vis Spectrophotometer LUS-B31
  • Wavelength range
  • 190 to 1100 nm
  • Spectral bandwidth
  • 1 nm
  • Wavelength Accuracy
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all

Nano Spectrophotometer

We produce a wide range of Nano spectrophotometer for qualitative and quantitative analysis of DNA/RNA in the sample. Our product is highly sensitive and requires only 0.5-2µl of sample for analysis.

Nano Spectrophotometer : Nano Spectrophotometer LNS-A10

Nano Spectrophotometer LNS-A10

  • Wavelength range
  • 200 - 800 nm
  • Path length
  • 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary)
  • Wavelength accuracy
  • ± 1 nm
Nano Spectrophotometer : Nano Spectrophotometer LNS-A21

Nano Spectrophotometer LNS-A21

  • Wavelength range
  • 200 - 850 nm
  • Path length
  • 1 mm, 2 mm, 5 mm, 10 mm
  • Wavelength accuracy
  • ± 1 nm
Nano Spectrophotometer : Nano Spectrophotometer LNS-B11
Nano Spectrophotometer LNS-B11
  • Wavelength range
  • 230 nm, 260 nm, 280 nm
  • Path length
  • 1.0 mm, 0.2 mm
  • Minimum Sample size
  • 0.3 - 2.0 µl
Nano Spectrophotometer : Nano Spectrophotometer LNS-C10
Nano Spectrophotometer LNS-C10
  • Cuvette
  • No
  • PC
  • Inbuilt
  • Wavelength range
  • 190 - 850 nm

Single Beam UV/Visible Spectrophotometer

We manufacture highly precise UV/Vis automatic scanning spectrophotometer with wavelength ranging from 190-1100nm. It can perform quantitative measurement, photometric measurement, spectrum scanning, DNA/Protein analysis. It is in demand for its user-friendly operations

Single Beam UV/Visible Spectrophotometer : Single Beam UV/Visible Spectrophotometer LUS-A10

Single Beam UV/Visible Spectrophotometer LUS-A10

  • Wavelength Range
  • 190 ~ 1100 nm
  • Spectral Bandwidth
  • 1 nm
  • Wavelength Accuracy
  • ± 0.3 nm
Single Beam UV/Visible Spectrophotometer : Single Beam UV/Visible Spectrophotometer LUS-A11

Single Beam UV/Visible Spectrophotometer LUS-A11

  • Wavelength Range
  • 190 ~ 1100 nm
  • Spectral Bandwidth
  • 1.8 nm
  • Wavelength Accuracy
  • ± 0.3 nm
Single Beam UV/Visible Spectrophotometer : Single Beam UV/Visible Spectrophotometer LUS-A20
Single Beam UV/Visible Spectrophotometer LUS-A20
  • Wavelength Range
  • 190 ~ 1100 nm
  • Setting Wavelength
  • Automatic
  • Spectral Bandwidth
  • 2 nm
Single Beam UV/Visible Spectrophotometer : Single Beam UV/Visible Spectrophotometer LUS-A21
Single Beam UV/Visible Spectrophotometer LUS-A21
  • Wavelength Range
  • 190 ~ 1100 nm
  • Setting Wavelength
  • Automatic
  • Spectral Bandwidth
  • 1.8 nm

Visible Spectrophotometer

Labtron provides extensive range of visible spectrophotometer LVS series which can operate over a wavelength range of 320-1100nm. It brings unmatched performance with outstanding accuracy and precision.

Visible Spectrophotometer : Vis Spectrophotometer LVS-A10

Vis Spectrophotometer LVS-A10

  • Wavelength Range
  • 330 to 1000 nm
  • Spectral Bandwidth
  • 5 nm
  • Wavelength Accuracy
  • ± 2 nm
Visible Spectrophotometer : Vis Spectrophotometer LVS-A11

Vis Spectrophotometer LVS-A11

  • Wavelength Range
  • 335 ~ 1000 nm
  • Spectral Bandwidth
  • 4 nm
  • Wavelength Accuracy
  • ± 2 nm
Visible Spectrophotometer : Vis Spectrophotometer LVS-B10
Vis Spectrophotometer LVS-B10
  • Wavelength Range
  • 325 ~ 1000 nm
  • Setting Wavelength
  • Automatic
  • Spectral Bandwidth
  • 2 nm
Visible Spectrophotometer : Vis Spectrophotometer LVS-C10
Vis Spectrophotometer LVS-C10
  • Wavelength Range
  • 320 ~ 1100 nm
  • Spectral Bandwidth
  • 4 nm
  • Wavelength Accuracy
  • ± 0.5 nm

Atomic Absorption Spectrophotometer

Labtron Atomic Absorption Spectrophotometer makes use of the modern in technology. It is acquired after thorough research into the desires of the diagnostic community. It has all the power, performance and speed necessitated in today’s modern laboratory.

Atomic Absorption Spectrophotometer : Atomic Absorption Spectrophotometer LAAS-A11

Atomic Absorption Spectrophotometer LAAS-A11

  • Wavelength range
  • 190 - 900 nm
  • Spectral Bandwidth
  • 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm
  • Wavelength accuracy
  • ≤ ± 0.5 nm
Atomic Absorption Spectrophotometer : Atomic Absorption Spectrophotometer LAAS-A20

Atomic Absorption Spectrophotometer LAAS-A20

  • Wavelength range
  • 180 - 900 nm
  • Spectral Bandwidth
  • 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting)
  • Wavelength accuracy
  • ≤ 0.15 nm
Atomic Absorption Spectrophotometer : Atomic Absorption Spectrophotometer LAAS-A21
Atomic Absorption Spectrophotometer LAAS-A21
  • Wavelength range
  • 180 – 900 nm
  • Spectral Bandwidth
  • 0 nm, 0.2 nm, 0.4 nm, 1.0 nm, 2.0 nm (5 steps with automatic changeover)
  • Wavelength accuracy
  • ≤ 0.15 nm
Atomic Absorption Spectrophotometer : Atomic Absorption Spectrophotometer LAAS-A22
Atomic Absorption Spectrophotometer LAAS-A22
  • Wavelength range
  • 180 – 900 nm
  • Spectral Bandwidth
  • 0.1 nm,0.2 nm,0.4 nm, 1.0 nm, 2.0 nm automatic setting
  • Wavelength accuracy
  • ≤ 0.15 nm

Table Top Spectrophotometer

Table Top Spectrophotometer : Table top spectrophotometer LTS-A10

Table top spectrophotometer LTS-A10

  • Illumination system
  • d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Size of integrated sphere
  • 40 mm, alvan diffused reflection surface coating
  • Illumination light source
  • CLED
Table Top Spectrophotometer : Table top spectrophotometer LTS-A11

Table top spectrophotometer LTS-A11

  • Illumination system
  • d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Size of integrated sphere
  • 40 mm, alvan diffused reflection surface coating
  • Illumination light source
  • CLED
Table Top Spectrophotometer : Table top spectrophotometer LTS-A12
Table top spectrophotometer LTS-A12
  • Illumination system
  • d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Size of integrated sphere
  • 15.2 cm, alvan diffused reflection surface coating
  • Illumination light source
  • CLED
Table Top Spectrophotometer : Table Top Spectrophotometer LTS-A16
Table Top Spectrophotometer LTS-A16
  • Wavelength Range
  • 360 nm to 780 nm
  • Wavelength Pitch
  • 10 nm
  • Sensor
  • Silicon Photodiode Array

Portable Spectrophotometer

Portable Spectrophotometer : Portable spectrophotometer LSP-A10

Portable spectrophotometer LSP-A10

  • Illumination
  • d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Repeatability
  • Light splitting reflectivity:standard deviation within 0.08% Color values:ΔE*ab
  • Sensor
  • Blue light enhanced sensor array
Portable Spectrophotometer : Portable spectrophotometer LSP-A11

Portable spectrophotometer LSP-A11

  • Illumination
  • d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Repeatability
  • Light splitting reflectivity:standard deviation within 0.08% Color values:ΔE*ab Maximum:0.03
  • Sensor
  • Dual light path sensor array
Portable Spectrophotometer : Portable spectrophotometer LSP-A12
Portable spectrophotometer LSP-A12
  • Illumination
  • d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Repeatability
  • Light splitting reflectivity:standard deviation within 0.08% Color values:ΔE*ab
  • Sensor
  • Photoelectric diode sensor
Portable Spectrophotometer : Portable spectrophotometer LSP-A13
Portable spectrophotometer LSP-A13
  • Illumination
  • d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Repeatability
  • Light splitting reflectivity:standard deviation within 0.08% Color values:ΔE*ab
  • Sensor
  • Photoelectric diode sensor

Fluorescence Spectrophotometer

Fluorescence Spectrophotometer : Fluorescence Spectrophotometer LFS-A10

Fluorescence Spectrophotometer LFS-A10

  • Light source
  • 150 W Xenon lamp
  • Excitation wavelength
  • 200 nm to 900 nm
  • Emission wavelength
  • 200 nm to 900 nm
Fluorescence Spectrophotometer : Fluorescence Spectrophotometer LFS-A12

Fluorescence Spectrophotometer LFS-A12

  • Light source
  • 150 W Xenon lamp
  • Excitation wavelength
  • 200 nm to 900 nm
  • Emission wavelength
  • 200 nm to 900 nm
Fluorescence Spectrophotometer : Fluorescence Spectrophotometer LFS-A11
Fluorescence Spectrophotometer LFS-A11
  • Excitation Source
  • 150 W Xenon Lamp
  • Excitation Wavelength
  • 200 nm to 900 nm
  • Excitation Slit
  • 1 nm, 2 nm, 5 nm, 10 nm, 20 nm

Xenon Lamp Spectrophotometer

Xenon Lamp Spectrophotometer : Xenon Lamp Spectrophotometer LXLS-A10

Xenon Lamp Spectrophotometer LXLS-A10

  • Optical system
  • Double Beam, Grating 1200 lines/mm
  • Wavelength Range
  • 190 nm to 1100 nm
  • Spectral Bandwidth
  • 2 nm
Xenon Lamp Spectrophotometer : Xenon Lamp Spectrophotometer LXLS-A11

Xenon Lamp Spectrophotometer LXLS-A11

  • Optical system
  • Double Beam, Grating 1200 lines/mm
  • Wavelength Range
  • 190 nm to 1100 nm
  • Spectral Bandwidth
  • 1 nm
Xenon Lamp Spectrophotometer : Xenon Lamp Spectrophotometer LXLS-A13
Xenon Lamp Spectrophotometer LXLS-A13
  • Optical system
  • Double Beam, Grating 1200 lines/mm
  • Wavelength Range
  • 190 nm to 1100 nm
  • Spectral Bandwidth
  • 2 nm
Xenon Lamp Spectrophotometer : Xenon Lamp Spectrophotometer LXLS-A14
Xenon Lamp Spectrophotometer LXLS-A14
  • Optical system
  • Double Beam, Grating 1200 lines/mm
  • Wavelength Range
  • 190 nm to 1100 nm
  • Spectral Bandwidth
  • 1 nm