Standard HPLC : HPLC system LHLC-B10


Share :



This HPLC system is incorporated with advanced high pressure injection technique. The detector is equipped with 24 bits AD transducer to assure low noise, low drift and high sensibility. This HPLC system can conveniently change the sample input volume. It comes with dual piston reciprocating and series pump for consistent and stable flow.



Available Range :

High pressure pump : Single pump High pressure pump : Two sets of pump High pressure pump : High pressure gradient pump High pressure pump : High pressure constant-current infusion pump
High pressure pumpHigh pressure gradient pump
Peak operating pressure45 MPa, Stainless steel pump
Pressure± 0.02 MPa
Flow rate range0.001 - 9.999 mL / min
Flow rate precision± 5 %
Flow rate repeatabilityRSD ≤ 0.1 %
Power220V ± 10 %, 50 Hz, 250 W
Size (W × H × D)520 × 420 × 160 mm
UV Detector
Wavelength190 - 680 nm
Wavelength error≤ ± 1 nm
Baseline noise≤ ± 2 × 10-5 AU (Methyl alcohol, 1 mL / min, 254 nm, 20 ºC)
Wavelength repeatability0.2 nm
Flow cell8 µL
Drift≤ 5 × 10-4 AU/h (Methyl alcohol, 1 mL / min, 254 nm, 20 ºC)
Limit of detection≤ 2 × 10-9 g / mL (Naphthalene methyl alcohol solvent)
Automatic Injector
Sample valueMaximum 2 mL, 6 × 25 = 150 units
Sample volume0 - 1mL, adjustable
Sample residual< 0.02 %
Column oven
Temperature controlRoom temperature ± 5 ºC - 80 ºC
Constant temperature accuracy± 1 ºC
Constant temperature precision≤ 0.1 ºC
Temperature setting resolution ratio0.1 ºC
Overall Instrument
Quantitative analysisRDS 6 ≤ 0.2 %
Quantitative repeatabilityRDS 6 ≤ 0.2 %
Sample residual≤ 0.01 %
Gradient error≤ 0.01 %
  • Inclusion of high performance patent gradient mixer
  • Intelligent anti-control software with powerful control function
  • Stand-alone TFT colour screen with touch control
  • High pressure gradient pump
This gradient HPLC system has multiple applications in medicine analysis, detection of protein content of food, environmental analysis, oil and chemical analysis and in scientific research studies.

Standard HPLC

Standard HPLC : HPLC system LHLC-A10

HPLC system LHLC-A10

  • High pressure pump
  • Single pump
  • Flow rate range
  • 0.001 - 9.999 mL / min (0.001 mL / min increment)
  • Pressure range
  • ≤ 0.5 MPa (0 - 42 MPa)
Standard HPLC : HPLC system LHLC-A11

HPLC system LHLC-A11

  • High pressure pump
  • Two sets of pump
  • Flow rate range
  • 0.001 - 9.999 mL / min (0.001 mL / min increments)
  • Pressure range
  • ≤ 0.5 MPa (0 - 42 MPa)
Standard HPLC : HPLC system LHLC-B11
HPLC system LHLC-B11
  • High pressure pump
  • High pressure constant-current infusion pump
  • Infusion Way
  • Micro volume series dual-piston
  • Infusion pressure
  • 0 - 9999 Psi

Analytical HPLC

Analytical HPLC : Analytical HPLC-A7840

Analytical HPLC-A7840

  • Pump Specifications
  • Double plunger series mode, floating plunger design, single stroke volume 30 µl
  • Detector Specifications
  • 190 to 700 nm
Analytical HPLC : Analytical HPLC-A7835

Analytical HPLC-A7835

  • Pump Specifications
  • HPP-B1
  • Detector Specifications
  • HPD-B2
Analytical HPLC : Analytical HPLC-A7832
Analytical HPLC-A7832
  • Detector Specifications
  • Model No HPD-A20 HPD-A21 Wavelength range Single wavelength ( 190 to 800 nm ) Dual wavelength ( 190 to 800 nm ) Wavelength accuracy ± 0.5 nm ± 2 nm Wavelength repeatability 0.15 nm 0.3 nm Band width 8 nm 8 nm Optical path 10 nm 10 nm Deuterium lamp 190 to 400 nm 190 to 400 nm Tungsten lamp 400 to 800 nm 400 to 800 nm Baseline noise ( Static ) Au ≤ ± 0.35 × 10-5 ≤ ± 0.5 × 10-5 Baseline drift ( Static ) Au / h ≤ 1 × 10-4 ≤ 1.5 × 10-4 Minimum detection limit ≤ 4 × 10-8 ≤ 4 × 10-8 Power 100 W 100 W Power supply 90 V / 50 to 60 Hz 90 V / 50 to 60 Hz Dimension 460 × 315 × 180 mm 460 × 315 × 180 mm Weight 9.5 kg 9.5 kg
  • Pump Specifications
  • 0.0001 to 10 ml / min
Analytical HPLC : Analytical HPLC System LAHS-A10
Analytical HPLC System LAHS-A10
  • Pump specification
  • Quaternary Low Pressure Pump
  • UV/VIS Detector
  • 190 to 800 nm
  • Data-processing Workstation
  • System contain the tables for regular samples Equipped with Internal and external standard calculation process Automatic display, print, export of data and starting of another program on completion on measurement Observe with the condition of 21 CFR part 11 directive of the FDA