Standard HPLC : HPLC system LHLC-A10


Share :



This HPLC system is equipped with high-pressure constant-current pump and UV detector. Pressure pulsation is controlled by diaphragmatic damper in seconds. The UV detectors helps in identification of samples and elutes that are colourless, odourless in nature. There is auto boot detection function available in this HPLC system.



Available Range :

High pressure pump : Single pump High pressure pump : Two sets of pump High pressure pump : High pressure gradient pump High pressure pump : High pressure constant-current infusion pump
High pressure pumpSingle pump
Flow rate range0.001 - 9.999 mL / min (0.001 mL / min increment)
Pressure range≤ 0.5 MPa (0 - 42 MPa)
Flow rate precisionRSD < 0.06 %
Pulsation≤ 0.1 MPa (flow rate 1 ml / min, Pressure 5 - 10 MPa)
Qualitative analysisRSD 6 ≤ 0.1 % (naphthalene methyl alcohol solvent)
Quantitative repeatabilityRSD 6 ≤ 0.3 % (naphthalene methyl alcohol solvent)
Flow rate setting errorSs ≤ 2 % (1 mL / min water, 5 - 10 MPa, room temperature)
Mixing accuracy± 1 %
Mixing precision± 0.2 %
Size (W × H × D)450 × 300 × 160 mm
UV Detector
Wavelength range190 - 680 nm
Flow cell8 µL
Spectrum band width8 nm
Baseline noise≤ ± 0.25 × 10-5 AU (empty cell)
Wavelength accuracy± 1 nm
Baseline drift≤ ± 0.4 × 10-4 AU (empty cell)
Wavelength precision< 0.1 nm
Limit of detection3 × 10-9 g / mL (naphthalene methyl alcohol solvent)
Size (W × H × D)450 × 300 × 160 mm
  • Limit baseline noise can be ensured using electronic pulse suppression technique
  • High pressure single pump
  • Easy to change gasket ring & automatic washing function for the column
  • User-friendly software for smooth operations
The HPLC has applications in separation of mixture of compounds in chemical analysis, poison analysis, environmental analysis, protein food detection, medicine testing, and polymer analysis.

Standard HPLC

Standard HPLC : HPLC system LHLC-A11

HPLC system LHLC-A11

  • High pressure pump
  • Two sets of pump
  • Flow rate range
  • 0.001 - 9.999 mL / min (0.001 mL / min increments)
  • Pressure range
  • ≤ 0.5 MPa (0 - 42 MPa)
Standard HPLC : HPLC system LHLC-B11

HPLC system LHLC-B11

  • High pressure pump
  • High pressure constant-current infusion pump
  • Infusion Way
  • Micro volume series dual-piston
  • Infusion pressure
  • 0 - 9999 Psi
Standard HPLC : HPLC system LHLC-B10
HPLC system LHLC-B10
  • High pressure pump
  • High pressure gradient pump
  • Peak operating pressure
  • 45 MPa, Stainless steel pump
  • Pressure
  • ± 0.02 MPa

Analytical HPLC

Analytical HPLC : Analytical HPLC-A7840

Analytical HPLC-A7840

  • Pump Specifications
  • Double plunger series mode, floating plunger design, single stroke volume 30 µl
  • Detector Specifications
  • 190 to 700 nm
Analytical HPLC : Analytical HPLC-A7835

Analytical HPLC-A7835

  • Pump Specifications
  • HPP-B1
  • Detector Specifications
  • HPD-B2
Analytical HPLC : Analytical HPLC-A7832
Analytical HPLC-A7832
  • Detector Specifications
  • Model No HPD-A20 HPD-A21 Wavelength range Single wavelength ( 190 to 800 nm ) Dual wavelength ( 190 to 800 nm ) Wavelength accuracy ± 0.5 nm ± 2 nm Wavelength repeatability 0.15 nm 0.3 nm Band width 8 nm 8 nm Optical path 10 nm 10 nm Deuterium lamp 190 to 400 nm 190 to 400 nm Tungsten lamp 400 to 800 nm 400 to 800 nm Baseline noise ( Static ) Au ≤ ± 0.35 × 10-5 ≤ ± 0.5 × 10-5 Baseline drift ( Static ) Au / h ≤ 1 × 10-4 ≤ 1.5 × 10-4 Minimum detection limit ≤ 4 × 10-8 ≤ 4 × 10-8 Power 100 W 100 W Power supply 90 V / 50 to 60 Hz 90 V / 50 to 60 Hz Dimension 460 × 315 × 180 mm 460 × 315 × 180 mm Weight 9.5 kg 9.5 kg
  • Pump Specifications
  • 0.0001 to 10 ml / min
Analytical HPLC : Analytical HPLC System LAHS-A10
Analytical HPLC System LAHS-A10
  • Pump specification
  • Quaternary Low Pressure Pump
  • UV/VIS Detector
  • 190 to 800 nm
  • Data-processing Workstation
  • System contain the tables for regular samples Equipped with Internal and external standard calculation process Automatic display, print, export of data and starting of another program on completion on measurement Observe with the condition of 21 CFR part 11 directive of the FDA