Maximum capacity | 22 L |
Temperature range | RT + 5 ℃ to 400 ℃ |
Temperature accuracy | ± 0.1 ℃ |
Temperature program | 9-phase/ 10 platform |
Temperature range | RT+ 7 ℃ to 420 ℃ |
Temperature control | Automatic |
Injector type | Column or split |
Maximum sample inlet | 3 pcs |
Temperature range | RT + 7 ℃ to 420 ℃ |
Maximum installation | Dual detector |
Flame ignition mode | Automatic |
Flame Ionization Detector (FID) | Logarithmic amplifier High voltage switch control Baseline signal display Ignition coil control Detection limit: ≤3 ×10 to 12 g/s (Sample: n-hexadecane) Baseline noise: ≤ 5 × 10 - 14 A Baseline draft: ≤ 6 × 10 -13 A Dynamic range: 10 7 RSD: ≤ 3 % |
Type | High pressure and low pulse double plunger tandem advection pump |
Maximum pressure | 35 MPa (PEEK) |
Pressure display accuracy | ≤ 0.1 MPa |
Flow stability | (0.2 to 0.5) ml/ min ≤ 3 % (0.5 to 1.0) ml/ min ≤ 2 % > 1.0 ml/ min 2 % |
Type | Temperature Control and Bipolar Conductivity Detector |
Detection mode | Bipolar conductivity detection |
Cell volume | ≤ 0.8 µL |
Detection range | 0 to 35000 µS/ cm |
Plastic flow path | Made of PEEK materials |
Six way Valve | PEEK material, 5000 psi pressure, independent automatic collection and flow function |
Inner volume | 300 µl |
Degassing volume | 7.5 ml |
Maximum flow rate | 10 ml/ min |
Degassing efficiency | Degassing 90 % at 1ml/ min |
Type | High pressure and low pulse double plunger tandem advection pump |
Maximum pressure | 35 MPa (PEEK) |
Pressure display accuracy | ≤ 0.1 MPa |
Flow stability | (0.2 to 0.5) ml/ min ≤ 3 % (0.5 to 1.0) ml/ min ≤ 2 % > 1.0 ml/ min 2 % |
Type | Temperature Control and Bipolar Conductivity Detector |
Detection mode | Bipolar conductivity detection |
Cell volume | ≤ 0.8 µL |
Detection range | 0 to 45000 µS/ cm |
Plastic flow path | Made of PEEK materials |
Six way Valve | PEEK material, 5000 psi pressure, independent automatic collection and flow function |
Type | High pressure and low pulse double plunger tandem advection pump |
Maximum pressure | 35 MPa (PEEK) |
Display pressure accuracy | ≤ 0.1 MPa |
Flow stability | (0.2 to 0.5) ml/ min ≤ 3 % , (0.5 to 1.0) ml/ min ≤ 2 %, > 1.0 ml/ min ≤ 2 % |
Maximum pressure | 35 MPa |
Contact material of the rotor | PEEK |
Control mode | By Stepper motor |
Power supply | DC 24 V |
Operating temperature range | Room temperature 20 to 60°C ( 68 to 140°F) |
Controlling temperature accuracy | ± 0.01°C |
Allowable deviation of column heater temperature | ± 2°C |
Temperature stability | ≤ 1°C/ h |
Plastic flow path | Made up of PEEK material |
Six way valve | PEEK material pressure 5000 psi, independent automatic collection and flow function |
Model No | GC-87 |
Flow rate | 1 ~ 1.5 ml / min |
Maximum flow rate | 10 ml / min |
Inlet temperature | 450 °C |
Model No | MS-89 |
Mass range | 1.5 ~ 1000 amu |
Ion – source temperature | 100 °C ~ 350 °C |
GC-MS interface temperature | 450 °C |
Type | High-pressure and low –pulse double plunger tandem advection pump |
Maximum Pressure | 35 MPa (PEEK) |
Flow Range | 0.001 to 9.999 mL/min |
Flow accuracy | ± 0.5 % |
Temperature range | Room temperature +5°C to 60°C (41 to 140°F) |
Allowable deviation | ± 1°C |
Temperature stability | ≤ 0.5°C/h |
Maximum pressure | 35 MPa |
Control mode | By stepper motor |
Power supply | 24 V (DC) |
Type | Temperature control and bipolar conductivity detector |
Detection type | Bipolar conductivity detection |
Cell volume | ≤ 0.8 µL |
Measurement range | 0 to 45000 µ S/cm (adjustable) |