Touch Thermal Cycler : Touch Thermal Cycler (Basic) LTCB-A10


Share :



Touch Thermal Cycler (Basic) LTCB-A10 comes with customized 8 pcs long service life Marlow (US) peltier heating units. Each thermal block has 4 independent temperature control sensors. With 5°C/s maximum ramping rate, this cycler saves operation time of user. Its 8 inch TFT touch screen with graphical real time display. With Windows OS, PC control function, print function, large storage capacity, USB connection, this cycler meets latest experimental demands.



Available Range :

Capacity : 96 × 0.2 ml Capacity : 60 × 0.5 ml Capacity : 384 well Capacity : 96 × 0.2 ml Capacity : 60 × 0.5 ml Capacity : Double (each block with) 48×0.2ml
Capacity96 × 0.2 ml
Block Temperature Range0 to 100℃
Temperature Control Accuracy≤ ± 0.1 ℃
Ramping Rate Adjustable0.1 - 5 ℃
Temperature Uniformity≤ ± 0.2 ℃
Heating Rate5 ℃/s
Cooling Rate4 ℃/s
Temperature Control ModeBlock \ Tube
Hot-lid Temperature Range30 to 110℃
Hot Lid Height AdjustableStepless Adjustable
Max No. of Steps30
Max No. of Cycles99
Time Increment/Decrement1 sec to 9 min 59 sec
Temperature Increment/Decrement0.1 to 9.9℃
Program10000 +(USB FLASH)
Pause FunctionYes
Auto Data ProtectionYes
PrintYes
LCD8 inch,800×600 Pixels, 16 colors TFT touch screen
CommunicationUSB 2.0 , LAN
Power Supply85 to 264 V AC , 47 to 63 Hz , 600 W
Dimension ( L×W×H )380 × 240 × 260 mm
Weight8.5 kg
  • 8” TFT color screen for easy monitoring
  • High heating and cooling rate
  • Step less adjustable hot lid with pressure protection
  • Built in in 11 standard program file template for quick editing of files
  • Real time display to show running status of experiment
  • One-click quick incubation function to meet different experimental needs
  • Internal flash memory for 10000 typical PCR files
  • User-friendly setting for hot lid temperature and hot lid work mode
  • Auto restart after power failure
  • Easy view of actual and target temperatures in real time
  • Support USB and LAN to update software
  • Supports email alert function when experiment is over
Widely used in PCR applications in research and development, food science, pharmaceuticals, life science, animal diagnostics and analytical laboratories.

Advanced Thermal Cycler

This series uses advanced Peltier based semi conductor technology for thermal uniformity. These products are steady, easy to operate and affordable.

Advanced Thermal Cycler : Advanced Thermal Cycler (Basic) LATB-A10

Advanced Thermal Cycler (Basic) LATB-A10

  • Capacity
  • 96 × 0.2 ml
  • Block Temperature Range
  • 0 to 99.9°C
  • Temperature Control Accuracy
  • ≤ ± 0.2 ℃
Advanced Thermal Cycler : Advanced Thermal Cycler (Basic) LATB-A11

Advanced Thermal Cycler (Basic) LATB-A11

  • Capacity
  • 96 × 0.2 ml + 77 × 0.5 ml
  • Block Temperature Range
  • 0 to 99.9°C
  • Temperature Control Accuracy
  • ≤ ± 0.2 ℃
Advanced Thermal Cycler : Advanced Thermal Cycler (Basic) LATB-A12
Advanced Thermal Cycler (Basic) LATB-A12
  • Capacity
  • 54 × 0.5 ml
  • Block Temperature Range
  • 0 to 99.9°C
  • Temperature Control Accuracy
  • ≤ ± 0.2 ℃
Advanced Thermal Cycler : Advanced Thermal Cycler (Gradient) LATG-A10
Advanced Thermal Cycler (Gradient) LATG-A10
  • Capacity
  • 96 × 0.2 ml
  • Block Temperature Range
  • 0 to 99.9°C
  • Temperature Control Accuracy
  • ≤ ± 0.2 ℃

Real Time PCR

Enhance your operating experience with our large sample capacity real time PCRs that offer a wide temperature range. With its unique block dissipation technology, it provides precise temperature control and thermal gradient which easily optimizes PCR assays. High throughput and maximum flexibility, these instruments are an affordable option for research applications.

Real Time PCR : Real Time PCR LRTP-A30

Real Time PCR LRTP-A30

  • Sample Capacity
  • 16×0.2 ml (2×8 well, double block)
  • Consumable
  • Clear 0.2 ml PCR tube/ 8-tube strips
  • Reaction Volume
  • 10 to 100 µl
Real Time PCR : Real Time PCR LRTP-A31

Real Time PCR LRTP-A31

  • Sample Capacity
  • 16×0.2 ml (2×8 well, double block)
  • Consumable
  • Clear 0.2 ml PCR tube/ 8-tube strips
  • Reaction Volume
  • 10 to 100 µl
Real Time PCR : Real Time PCR LRTP-A40
Real Time PCR LRTP-A40
  • Fluorescence Detection Channel
  • 4
  • Reactions Per Run
  • 96
  • Block Format
  • 96-well, 0.2 ml

Touch Thermal Cycler

The series is designed with the 8” TFT colour screen for easy observation and advanced windows operating system. It consists of replaceable double block that can function separately.

Touch Thermal Cycler : Touch Thermal Cycler (Basic) LTCB-A11

Touch Thermal Cycler (Basic) LTCB-A11

  • Capacity
  • 60 × 0.5 ml
  • Block Temperature Range
  • 0 to 100℃
  • Temperature Control Accuracy
  • ≤ ± 0.1 ℃
Touch Thermal Cycler : Touch Thermal Cycler (Basic) LTCB-A12

Touch Thermal Cycler (Basic) LTCB-A12

  • Capacity
  • 384 well
  • Block Temperature Range
  • 0 to 100℃
  • Temperature Control Accuracy
  • ≤ ± 0.1 ℃
Touch Thermal Cycler : Touch Thermal Cycler (Gradient) LTCG-A10
Touch Thermal Cycler (Gradient) LTCG-A10
  • Capacity
  • 96 × 0.2 ml
  • Block Temperature Range
  • 0 to 100℃
  • Temperature Control Accuracy
  • ≤ ± 0.1 ℃
Touch Thermal Cycler : Touch Thermal Cycler (Gradient) LTCG-A11
Touch Thermal Cycler (Gradient) LTCG-A11
  • Capacity
  • 60 × 0.5 ml
  • Block Temperature Range
  • 0 to 100℃
  • Temperature Control Accuracy
  • ≤ ± 0.1 ℃

Advanced PCR System

Advanced PCR System : PCR System LPRS-A10

PCR System LPRS-A10

  • Capacity
  • 96 × 0.2 ml
  • Tube
  • 0.2 ml tube, 8 strips, 96 wells plate
  • Max. Ramp Rate
  • 0.5°C/s
Advanced PCR System : PCR System LPRS-A11

PCR System LPRS-A11

  • Capacity
  • 6 × 16 × 0.2 ml
  • Tube
  • 0.2 ml tube, 8 strips, 96 wells plate
  • Max. Ramp Rate
  • 0.6°C/s
Advanced PCR System : PCR System LPRS-A12
PCR System LPRS-A12
  • Capacity
  • 96 × 0.2 ml
  • Tube
  • 0.2 ml tube, 8 strips, 96 wells plate
  • Max. Ramp Rate
  • 0.7°C/s