Generate Catalog For :

Atomic Absorption Spectrophotometer LAAS-A21

www.labtron.info

Personalized PDF Catalog

Catalog Generated On : 11/09/2025


Atomic Absorption Spectrophotometer : Atomic Absorption Spectrophotometer LAAS-A21

Atomic Absorption Spectrophotometer LAAS-A21

Description :

Atomic Absorption spectrophotometer comes with flame, graphite furnace and hydride generation system to meet different customer demand. It consist of 1800/mm reticle large are grating monochromator and titanium burner to improve the analysis efficiency and accuracy of the flame. Atomic Absorption spectrophotometer has manual 3 lamp holder configuration & 3 independent lamp power supply for analysis.

Specifications :

Wavelength range 180 – 900 nm
Spectral Bandwidth 0 nm, 0.2 nm, 0.4 nm, 1.0 nm, 2.0 nm (5 steps with automatic changeover)
Wavelength accuracy ≤ 0.15 nm
Wavelength repeatability ± 0.1 nm
Baseline drift ≤ ± 0.002 Abs / 30 min (Static) ≤ ± 0.005 Abs / 30 mins (Dynamic)
Absorbance Range 0 - 4 A
Lamp holder ≤ 3 lamps automatic turret, automatic alignment
Lamp power supply mode pulsed power supply
Optical System large 1800 /mm grating ruling, full closed optical system
Atomization Chamber Polymer explosion-proof spray chamber
Characteristic concentration (Cu) 0.015 μg / mL / 1 %
Detection Limit (Cu) 0.002 μg/mL
Burner Full titanium combustion head, 50 mm or 100 mm general combustion head
Nebulizer Atomizer efficient glass atomizer,can also be customized
Precision RSD ≤ 0.5 %
Ignition Type Microcomputer control, automatic ignition
Gas Control Automatic gas control system
Measurement Flame method, Hydride generation-Atomic absorption method
Concentration calculation Standard curve method(1 - 3 times curve), automatic fitting
The number of repeated measurements 1 to 99, automatic calculation of average concentration, standard deviation, relative standard deviation.
Print results Print the final stages of test data or analysis. The results can be exported into Excel worksheet.

Features :

  • 1800 /mm reticle (dispersion rate) large area grating monochromator
  • High performance hollow cathode lamp
  • Titanium burner for the flame analysis
  • Polymer automization chamber
  • Automatic analysis for sensitivity and reproducibility
  • High precision automatic optical system
  • Flame, graphite furnace operating mode can be switched automatically
  • Light source 3 lamp holder
  • Convenient data processing & sharing & printing
  • Powerful software with automatic instrument and additional control

Applications :

Atomic absorption spectrophotometer is widely used in analysis of elements from the mixture in scientific research, environmental science, metallurgy, agriculture & chemical industry, food, mining, and petrochemical, pharmaceutical industries.


www.labtron.info

www.labtron.info

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom